Fire-resistant boards and wall assemblies for projects requiring documented system performance.
Product advantages
Fire-resistant board options
Complete wall-system approach
Framing and insulation coordination
Test documentation by selected system
Product introduction
Fire-Resistant Gypsum Board
Fire-board composition
The fire-resistant board adds reinforcing fibers and functional additives to the gypsum core and uses a red facing for identification. It provides the board layer for internal fire-resistant walls and ceilings, while the required resistance period belongs to the complete tested assembly.
Brochure performance reference
The brochure lists 9.5 and 12 mm boards at 1200 × 3000 mm, stability under fire of at least 20 minutes, transverse breaking load of at least 180 N and mass per area no more than 11 kg/m². These are board indicators, not a wall or ceiling fire-resistance period.
Matching the tested system
The inquiry must identify the target period, board layers and thickness, framing section and centres, cavity insulation, screw spacing, joints and openings. Haice matches reports to the proposed brand, model and construction rather than substituting a single board test for an assembly result.
Reference specification
Model and technical data
Specifications, packing and standards are grouped for direct buyer review
Brochure reference size
1200 × 3000 mm
Thickness
9.5 / 12 mm
Stability under fire
≥20 minutes
Transverse breaking load
≥180 N
Mass per area
≤11 kg/m²
System rating
Confirmed by complete tested construction
Standards and documents
GB/T 9775-2008GB 6566-2010GB 8624-2012
Confirm before ordering
Application, installation area and target performance
Length, width, thickness, edge or profile section
Quantity, mixed-loading plan and destination port
Packing language, shipping marks, labels and required test reports
Reference data is based on the Taishan fire-resistant gypsum board series. A board alone does not establish a wall or ceiling fire rating.